Recalling the Registered Panel Setups

PSR-OR700 Owner’s Manual

135

Registering and Recalling Custom P

anel Setups

4

Use the [E] button to determine how Registration Sequence behaves
when reaching the end of the sequence (SEQUENCE END).
STOP .....................Pressing the TAB [®] button or the “advance” pedal has

no effect. The sequence is “stopped.”

TOP .......................The sequence starts again at the beginning.
NEXT BANK...........The sequence automatically moves to the beginning of

the next Registration Memory Bank in the same folder.

5

Program the Sequence order.
The numbers shown at the lower part of the display correspond to the REG-
ISTRATION MEMORY [1]–[8] buttons on the panel.
Program the Sequence order from left to right.

Press one of the REGISTRATION MEMORY [1]–[8] button on the
panel, then press the [6
π

π

π

π†

] (INSERT) button to input the number.

• Replacing the number

Press the [5π†] (REPLACE) button to replace the number at the cursor
position with the currently selected Registration Memory number.

• Deleting the number

Press the [7π†] (DELETE) button to delete the number at the cursor
position.

• Deleting all numbers

Press the [8π†] (CLEAR) button to delete all numbers in the sequence.

6

Press the [F] button to turn the Registration Sequence function on.

7

Press the [DIRECT ACCESS] button, then the [EXIT] button to return to
the Main display and confirm whether the Registration Memory num-
bers are called up according to the sequence programmed above.
• Use the TAB [®] button to call up the Registration Memory numbers in the

order of the sequence, or use the TAB [√] button to call them up in
reverse order. The TAB [√][®] buttons can only be used for Registration
Sequence when the Main display is called up.

• When pedal operation has been set in step 3, you can use a pedal to select

the Registration Memory numbers in order. The pedal can be used for Reg-
istration Sequence no matter which display is called up (except for the dis-
play in step 3).

Saving the Registration Sequence Settings

The settings for the Sequence order and how Registration Sequence behaves when
reaching the end of the sequence (SEQUENCE END) are included as part of the
Registration Memory Bank file. To store your newly programmed Registration
Sequence, save the current Registration Memory Bank file.

1

Press the REGIST BANK [+] and [–] buttons simultaneously to call up
the REGISTRATION BANK Selection display.

2

Press the [6

] button to save the Bank file (page 67).

CAUTION

Settings in the REGISTRATION
SEQUENCE display are auto-
matically saved to the instru-
ment when you exit from this
display. However, if you turn
the power off without exiting
from this display, the settings
will be lost.

Returning to the first
Sequence in one action
In the Main display, press the
TAB [√] and [®] buttons simul-
taneously. This cancels the cur-
rently selected Sequence
number (the box indicator at the
top right goes out). The first
Sequence will be selected by
pressing one of the TAB [√][®]
buttons or by pressing the pedal.

The Registration Sequence is indicated at the top
right of the Main display, letting you confirm the
currently selected number.

CAUTION

Keep in mind that all Registra-
tion Sequence data is lost
when changing Registration
Memory Banks, unless you’ve
saved it with the Registration
Memory Bank file.