York STELLAR PLUS E*FH060 User Manual

Page 4

background image

036-21031-004 Rev. A (0603)

4

Unitary Products Group

- = Not applicable

COOLING CAPACITY - With Air Handler Coils

UNIT

MODEL

AIR HANDLER

COIL MODEL

1

1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.

COOLING

MODEL

ELECTRIC
HEAT KW

2

2. Single phase units require single phase 2HK heaters.

W

RATED

CFM

NET MBH

SEER

W/O TXV

SEER

+ TXV

3

3. TXV = Use 1TV700 Series Kit.

EER

TOTAL SENS.

1 Phase 12 SEER HP / N1AH / G2FD

E4FH018

N1AHB08

2,5,7.5,10

17

G2FD024(S,H)17

650

19.0

14.3

12.05

---

10.65

N1AHB08

2,5,7.5,10

17

G2FD030(S,H)17

650

19.4

14.6

12.15

---

10.70

E4FH024

N1AHB08

2,5,7.5,10

17

G2FD024(S,H)17

800

23.4

17.6

12.10

---

10.85

N1AHB08

2,5,7.5,10

17

G2FD030(S,H)17

850

23.4

17.6

12.10

---

10.85

N1AHB08

2,5,7.5,10

14

G2FD035(S,H)14

850

23.4

17.6

12.10

---

10.85

E4FH030

N1AHB12

5,7.5,10,15,18

17

G2FD036(S,H)17

1000

29.0

21.8

---

12.40

10.65

E4FH036

N1AHB12

5,7.5,10,15,18

17

G2FD036(S,H)17

1200

34.6

25.6

--

12.00

10.50

E4FH042

N1AHC16

5,7.5,10,15,20

21

G2FD042(S,H)21

1400

40.0

29.6

--

12.00

10.50

N1AHC16

5,7.5,10,15,20

21

G2FD048(S,H)21

1425

41.0

30.3

--

12.40

10.80

E5FH048

N1AHC16

5.7.5,10,15,20

21

G2FD048(S,H)21

1600

47.5

35.6

--

12.00

10.50

N1AHD20

5.7.5,10,15,20,25,30

24

G2FD060(S,H)24

1620

48.0

36.0

--

12.40

10.85

E4FH060

N1AHD20

7.5,10,15,20,25,30

24

G2FD060(S,H)24

1850

58.0

42.0

--

12.00

10.70

N1AHD20

7.5,10,15,20,25,30

24

G2FD061H24

1875

58.5

41.5

--

12.20

10.70

1 Phase 12 SEER HP / N1VS / G2FD

E4FH018

N1VSB12

5,7.5,10,15,18

17

G2FD024(S,H)17

650

19.4

14.3

13.35

---

11.70

E4FH024

N1VSB12

5,7.5,10,15,18

17

G2FD024(S,H)17

800

24.0

18.0

14.00

---

12.00

E4FH030

N1VSB12

5,7.5,10,15,18

17

G2FD030(S,H)17

1000

29.0

21.8

---

13.00

11.20

N1VSB12

5,7.5,10,15,18

17

G2FD036(S,H)17

1000

29.2

21.9

---

13.50

11.40

E4FH036

N1VSB12

5,7.5,10,15,18

17

G2FD036(S,H)17

1200

35.0

25.9

--

12.80

11.20

E4FH042

N1VSC16

5,7.5,10,15,20

21

G2FD042(S,H)21

1400

40.5

30.0

--

12.80

11.20

N1VSC16

5,7.5,10,15,20

21

G2FD048(S,H)21

1425

41.5

30.7

--

13.50

11.40

E5FH048

N1VSC16

5.7.5,10,15,20

21

G2FD048(S,H)21

1600

48.0

36.0

---

13.40

10.50

N1VSD20

5.7.5,10,15,20,25,30

24

G2FD060(S,H)24

1650

49.0

36.8

---

13.80

10.80

E4FH060

N1VSD20

7.5,10,15,20,25,30

24

G2FD060(S,H)24

1850

60.5

42.9

--

13.00

11.60

N1VSD20

7.5,10,15,20,25,30

24

G2FD061H24

1875

59.0

41.5

--

12.60

11.90

1 Phase 12 SEER HP / F2RP / FP / FV

4,5

4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC

.

models. All ratings remain the same.

5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard.

E4FH018

F2RP/F2FP018

5,8,10

18

--

650

18.0

13.5

12.00

---

10.75

F2RP/F2FP024

5,8,10

18

--

650

19.0

14.3

12.50

---

10.50

E4FH024

F2RP/F2FP024

5,8,10

18

--

800

23.4

17.6

12.00

---

10.35

F2RP/F2FP030

5,8,10,15

18

--

800

23.8

17.9

---

12.50

10.55

E4FH030

F2RP/F2FP030

5,8,10,15

18

---

1035

28.2

21.2

---

12.00

10.30

F2RP/F2FP036

5,8,10,15

21

---

1035

29.0

21.8

---

12.00

10.30

E4FH036

F2RP036

5,8,10,15

18

--

1250

34.6

25.6

--

12.10

10.60

F2RP042

5,8,10,15

21

--

1250

34.6

25.6

--

12.10

10.50

E4FH042

F2RP042

5,8,10,15

21

--

1400

40.0

29.6

--

12.00

10.40

F2FP048

10,15,20,25

24

--

1600

41.0

30.3

--

12.40

10.80

E5FH048

F2FP048

10,15,20,25

24

--

1600

47.0

35.3

---

12.00

10.45

F2V060

10,15,20,25

24

--

1600

48.5

36.4

---

13.00

11.60

F2FP060

10,15,20,25

24

--

1600

47.5

35.6

---

12.00

10.35

E4FH060

F2FP060

10,15,20,25

24

--

1850

57.0

42.2

--

11.60

10.40

F2FV060H24

10,15,20,25

24

--

1875

59.0

43.0

--

13.00

11.60

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210/240.
Cooling MBH based on 8

0

°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input
in watt-hours during the same period.