VES-1616/24FA-5x Series Support Notes

All contents copyright 2008 ZyXEL Communications Corporation.

7

5. Enter “ATGO” to restart the switch after file transfer and the configuration

backup processes are complete. .

Using FTP:
1. Download (and unzipped) the correct model firmware to your computer.
2. Launch the FTP client on your PC to log into the switch. (From the command

prompt, type “ftp

3. Press [ENTER] when prompted for a user name
4. Enter the administrator login password to access the switch and display FTP

prompt.

5. Enter “bin” to set the transfer mode to binary.
6. Use “get” to transfer the configuration file from the switch to your computer, for

example: “get config config.rom” transfers the configuration file on the switch
(config) to your computer and renames it “config.rom”.

7. Enter “bye” to log out from the switch.

Load Factory Defaults

Using the Web Configurator:
1. Click Management > Maintenance in the navigation panel to display the

following screen.


2. Click “Click Here” link for Load Factory Default.
3. A dialog box pops up with the “Are you sure you want to load factory defaults?”

prompt.