Advanced function values, F01 auto display scanning, F02 display sleep – Xantrex Technology Link 1000 User Manual
Page 37: Advanced function values” on
About Link 1000 Settings
29
Advanced Function Values
The Link 1000 has sixteen advanced functions. The default
setting is appropriate for most, and you should not change a
value unless you understand the consequence of the change.
How to Enter Setup Mode and Change a Value: Reminder
The procedure for entering Setup mode and changing a value
is given on
.
F01 Auto Display Scanning
Default:
Off
Range:
Off, On
When Auto Display Scanning is On, the display
automatically scrolls through Volts, Amps, Ah, and Time
remaining. Each value is displayed for four seconds.
If Second Battery Voltage Sense (F11) is also on, two
voltages are shown. The flashing Volts status LED
indicates that the voltage displayed is that of the second
battery bank.
F02 Display Sleep
Default:
On
Range:
On, Off
This function turns off the Numeric Display and the Display
Units LEDs. All the other LEDs—
BATTERY
STATUS
light
bar,
AC
IN
, Charger status LEDs,
CHARGE
LED, and
INVERT
LED—stay on.
Note: If you are monitoring more than one battery:
•
Change Function F11, Second Battery Voltage Sense.
•
Record the software revision number on