2 snmp traps, 3 configuring snmp, 2 snmp traps 15.6.3 configuring snmp – ZyXEL Communications P-660HW-T v2 User Manual
Page 201: Figure 112 remote management: snmp, Table 79 snmp traps

P-660HW-T v2 User’s Guide
Chapter 15 Remote Management Configuration
201
15.6.2 SNMP Traps
The ZyXEL Device will send traps to the SNMP manager when any one of the following
events occurs:
15.6.3 Configuring SNMP
To change your ZyXEL Device’s SNMP settings, click Advanced > Remote MGMT >
SNMP. The screen appears as shown.
Figure 112 Remote Management: SNMP
Table 79 SNMP Traps
TRAP # TRAP NAME
DESCRIPTION
0
coldStart (defined in RFC-1215)
A trap is sent after booting (power on).
1
warmStart (defined in RFC-1215)
A trap is sent after booting (software reboot).
6
whyReboot (defined in ZYXEL-
MIB)
A trap is sent with the reason of restart before
rebooting when the system is going to restart (warm
start).
6a
For intentional reboot:
A trap is sent with the message "System reboot by
user!" if reboot is done intentionally, (for example,
download new files, CI command "sys reboot", etc.).
6b
For fatal error:
A trap is sent with the message of the fatal code if the
system reboots because of fatal errors.