beautypg.com

ZyXEL Communications 56K User Manual

Page 31

background image

User's Guide for ZyXEL Omni 56K and Omni 56K Plus Modems

3-11

With the type 1 connection, the dial-in (remote) modem will send in its supervisor password for

checking at the initial connection handshake, and the local modem will check this password against

its pre-stored acceptable password list. With a type 2 connection, the remote terminal will be

prompted to enter the password at the initital connection and the local modem will do the password

checking.

Two levels of security are provided. With level 1 security, the local modem will maintain the

connection if the password check is OK, otherwise the line will be disconnected. With level 2

security, the local modem will disconnect the line if the password has been found in its pre-stored

acceptable list and then will dial back the phone number corresponding to the dial-in password. The

line will be simply disconnected if the password does not march.

4 user passwords may be defined. The corresponding.4 dial-back numbers are the modem’s 4

stored phone numbers. Any character(ASCII 0-127) can be used in the password, the maximum

password length is 8 characters.

The security functions are only accessible through AT commands in terminal mode. Any access

attempt will result in the modem’s prompting to enter the supervisor password. The attempt will be

rejected if the entered password is not correct. The default supervisor password is ZyXEL when the

modem is shipped from the factory. This supervisor password is also the password sent for

automatic password checking in a type 1 connection. To modify the supervisor password, use

AT*HS

You will be asked for the original password and a new password and then to re-enter the new

password for verification. For example:

PASSWORD

(Enter supervisor password)

********

PASSWORD

(Enter new supervisor password)

********