86037680p4-19, Machine troubleshooting – Windsor Saber Glide 10052530 User Manual
Page 42

MACHINE TROUBLESHOOTING
SGJ32 86037680 01/03/07
4-19
PROBLEM
CAUSE
ERROR
CODE
SOLUTION
Vacuum motor does not run, 
or runs slowly 
Recovery tank full
Drain recovery tank
Recovery tank float 
switch dirty 
Clean float switch
Loose motor connection
7700
Check motor wires and 
connections 
Worn vacuum motor 
brushes 
Replace brushes, check 
commutator 
Poor scrubbing performance
Debris caught in scrub 
brushes 
Remove debris
Worn brushes or pads
Replace brushes or pads
Improper detergent, 
brush or pad used 
Contact equipment or 
application specialists 
Low scrub brush down 
pressure 
Increase brush pressure
Low battery charge
Charge batteries
Little or no solution flow to the 
floor 
Solution tank empty
Fill solution tank
Solution flow turned off 
or set too low 
Turn on or increase flow 
setting 
Solution strainer plugged
Clean solution strainer
Solution system 
plumbing obstructed 
Clear obstruction from 
plumbing 
Solution solenoid valve 
obstructed or stuck 
Clean or replace valve
Vent hole in solution 
tank lid obstructed 
Clear obstruction from vent 
hole 
Faulty solenoid valve 
connection 
Check wiring to solution valve
Brush motors do not run, or 
run slowly 
Circuit breaker(s) tripped
7600
Reset circuit breaker(s)
Low battery charge
Charge battery
Loose connection
7600
Check motor wires and 
connection 
Worn brush motor 
brushes 
Replace brushes, check 
commutator 
Scrub deck will not go 
down/up 
Faulty actuator
9000
Repair/replace actuator
Loose connection
9000
Check motor wires and 
connections 
Scrub deck goes down, then 
raises 
No brushes or pad 
drivers on machine 
9000
Install brushes or pad drivers
Error code not listed is 
displayed 
Controller detects 
electrical problem 
Contact service technician
 
 