86037680p4-2, Maintenance, Warning ! warning ! warning – Windsor Saber Glide 10052530 User Manual
Page 25: Warning

MAINTENANCE
SGJ32 86037680 01/03/07
4-2
!
WARNING
!
WARNING
!
WARNING
SPECIFIC GRAVITY
BATTERY CONDITION
1.265 100%
CHARGED
1.225 75%
CHARGED
1.190 50%
CHARGED
1.155 25%
CHARGED
1.120 DISCHARGED
!
WARNING
 
1. BATTERIES 
The batteries provide the power to operate the 
machine. The batteries require regular maintenance 
to keep them operating at peak efficiency. 
To get the greatest life from the batteries charge 
them when their charge level reaches 25%of a full 
charge. Use a hydrometer to check the charge 
level. 
Do not allow the batteries to remain in a discharged 
condition for any length of time. Never expose a 
discharged battery to temperatures below freezing. 
Discharged batteries will freeze causing cracked 
case. Do not operate the machine if the batteries 
are in poor condition or if they have a charge level 
below 25%, specific gravity below 1.177. 
Keep all metallic objects off the top of the batteries, 
as they may cause a short circuit. Replace worn or 
damaged cables and terminals. 
Check the electrolyte level in each battery cell 
before and after charging the batteries. Never add 
acid to the batteries, use water. Do not allow water 
level to fall below the battery plates. Portions of 
plates exposed to air will be destroyed. Do not 
overfill. Keep plugs firmly in place at all times. 
 
When servicing machine, 
avoid contact with acid. 
Batteries emit hydrogen gas. 
Explosion or fire can result. 
Keep sparks and open flame away. Keep covers 
open when charging. 
 
Wear eye protection and 
protective clothing when 
working with batteries. 
 
Charge batteries in a well 
ventilated area. 
BATTERY MAINTENANCE
1. When cleaning the batteries, use a solution of
baking soda and water. Do not allow the 
cleaning fluid to enter the battery cells. 
Electrolyte will be neutralized. 
2. Maintain the proper electrolyte level in each
battery cell. If a cell should accidentally 
overflow, clean immediately. 
3. Do not add water until the battery is fully
charged.
4. Wipe off the top of the batteries at least once a
week.
5. Test battery condition with a hydrometer at least
once a week.
 
 
 
 
 
6. Ensure that all connections are tight and all 
corrosion removed.
7. Every 4 to 6 months, remove the batteries from
the machine and clean the battery cases and 
battery compartment. 
NOTE: Do not take readings immediately after 
adding water. If the water and acid are not 
thoroughly mixed, the reading may not be accurate. 
 
To find the correct specific gravity reading when the 
temperature of the battery electrolyte is other then 
80
' F (27' C).
Add (+) to the specific gravity reading 
0.004 (4 points), for each 10
' F (6' C) above 80' F
(27
' C) Subtract (-) from the specific gravity reading
0.004 (4 points), for each 10
' F (6' C) below 80' F
(27
' C).