Interactive pen display

CALIBRATING THE PEN DISPLAY

You must calibrate the pen display to align the screen cursor with the position of the pen on the display
screen. This is required to compensate for viewing angle, and to adjust for parallax caused by the display
screen cover glass. Set the pen display in its working position, then follow the below procedure.

Important: When using a VGA connection,

be sure the display is properly
adjusted before calibrating.
See

adjusting the display

and

adjusting pitch and phase (VGA only)

.

1. Open the Wacom Tablet control panel.

If more than one pen display is installed
on your system, select the unit you are
working with from the T

ABLET

list.

2. Select P

EN

from the T

OOL

list.

Then select the C

ALIBRATE

tab.

3. If you are working with multiple monitors,

select the M

ONITOR

corresponding to the

pen display. (Only monitors that are set
to one of the resolutions supported by
the unit will appear in the list.)

4. Click C

ALIBRATE

... to activate the

calibration screen.

5. Hold the pen and position your head as

you normally do when working with the
pen display. Use the pen tip to click on
the center of the crosshairs in the upper-
left corner.

6. Then click on the center of the crosshairs

that are displayed in the lower-right
corner.

7. Test the alignment by positioning the pen

at a few different points on the display.
Click OK to accept the calibration.
Click T

RY

A

GAIN

to recalibrate.

Note: Read the directions in the calibration

screen for detailed instructions and
additional options. The calibration
setting applies to all applications.

Crosshairs

Tip:

To see the screen cursor slightly offset from the actual position of the pen tip, calibrate by
clicking on a spot showing that offset from the crosshairs. For example, to have the screen cursor
appear 2.5 mm (1/10th of an inch) above and to the left of the pen tip, calibrate by clicking on a
spot 2.5 mm (1/10th of an inch) below and to the right of the crosshairs.