Step 6: Modify Label Scheme

Installation

If your combination of wires is not shown, refer to the cross reference chart below. add the

corresponding Wayne-Dalton terminal designation label to your wire’s label and then repeat

Step 5 to match your wiring diagram. If a match is still not successful, contact customer

support at 1-866-545-5765, e-mail at [email protected] or contact your

HVaC professional.
note:

The C wire (24 Volts AC) is not optional. If a C wire is not present, your Z-Wave

®

Enabled Thermostat will not operate, contact customer support for options.

Cross reference Chart

Your Wires

R or V or VR

RH or R4

RC

W

W2

Y

Y2

G or F
C or X

E

L

T

B or

O

B and O

Z-Wave

®

Enabled Thermostat Terminal Designation

RH and Jumper 3 ON - Single power for Heat and Cool
RH and Jumper 3 OFF - Power for Heat
RC and Jumper 3 OFF - Power for Cool
W - Heat Control
W2 - 2nd stage Heat
Y - Cool Control
Do not connect and wrap exposed end with insulating electrical tape (2nd stage cool control
is not supported)
G - Fan Control
C - Common 24 VAC power (to power thermostat)
Do not connect and wrap exposed end with insulating electrical tape (Emergency heat is
supported by placing jumper 2 in the Aux position)
Do not connect and wrap exposed end with insulating electrical tape (System Monitor is not
supported)
Do not connect and wrap exposed end with insulating electrical tape (Outdoor Sensor is not
supported)
B - Heat pump changeover (cool to heat, powered in heat)
O - Heat pump chageover (heat to cool, powered in cool)
If there are both B and O wires (typical of Trane Heat Pumps), DO NOT CONNECT B to B
terminal, Re-label B as C.

Common Designations for normal Gas, oil and Electric systems and Heat pump Systems

Common Designations for

Zoned Hot Water Systems

Your Wires

R

W

Terminal Designation

RH
W

Your Wires

R or V or VR

Y or W or W2

M or Y

G or F

C or X or X2

R or O

Terminal Designation

RH
W2
Y
G
C
O

Your Wires

R

W

Y(3rd Wire)

Terminal Designation

RH
W
A

Your Wires

R

W

Y(3rd Wire)

Terminal Designation

RH
A
W

3 Wire Zoned Hot Water Solenoid Valves

3 Wire Zoned Hot Water Motor Drive Valves

2 Wire Zoned Hot Water

Common Designations for

Lennox Heat pump Systems

Common Designations for Trane
Systems (american Standard)

Your Wires

B
W or W1

Terminal Designation

C
W2