Installation, Unpacking the machine, Anchoring and handling the machine – Wilton FK350-4 User Manual
Page 9: Electrical connections
9
Installation
Unpacking the machine
Do not handle the packed
machine using slings.
To install the machine, first remove the packing,
paying particular attention not to cut any electric
wires or hydraulic hoses. Lift using straps
(Figure 3).
Figure 3
Anchoring and handling the machine
The base of the machine must be anchored to
the floor by two lag bolts or studs properly
anchored into concrete.
Electrical Connections
All electrical connections
must be done by a qualified
electrician. All adjustments or repairs must
be done with the machine disconnected from
the power source, unplugged. Failure to
comply may result in serious injury!
FK350-2 and FK350-2SX are rated at 220V.
FK350-4 and FK350-4SX are rated at 440V.
These machines not supplied with a plug. Use a
plug and outlet rated at least 20amps. The
circuit for the machine should also be protected
by at least a 20 amp circuit breaker or fuse.
Make sure that the blade turns in the correct
direction. If it does not, simply reverse two of
the phase wires on the supply input.
The sawing machine is now ready for use.