Multiple modulating boilers, Direct heating wiring diagram, Bmc and bmc-6x installation and operation manual – Weil-McLain BMC-6X User Manual

Page 30: 20ma modulating outputs voltage modulating outputs

background image

30

BMC and BMC-6X Installation and Operation Manual

MULTIPLE MODULATING BOILERS

DIRECT HEATING WIRING DIAGRAM

Boiler 1

Boiler 2

Boiler 3

Boiler 4

Boiler 1

Boiler 2

Boiler 3

Boiler 4

4 - 20 mA

Signal Outputs

Out

door S

ensor

S

y

st

em S

ensor

P

ro

v

e Jumper

D

o

Not r

emo

v

e

BMC

SYSTEM

A

B

C

D

Full Modulation Sequencing Control

1

2

RUN

PROGRAM

DO NOT APPLY ANY VOLTAGE

TO INPUT TERMINALS

3

4

5

6

7

8

9 10 11 12

13

15

14

17

16

18

22

20

19

21

24

23

29

25

27

26

28

32

30 31

L N

-

+

+

T

T

O

O

RS-485

mA

GND

VLT

SYS

A

B

C

D

PWR

CUR / VLT

A

-

+

+

mA

GND

VLT

-

+

+

mA

GND

VLT

-

+

+

mA

GND

VLT

+

mA

TEMP

OUTDOOR

O

O

TEMP

SYSTEM

EXTENSION

MODULE

CUR / VLT

B

CUR / VLT

C

CUR / VLT

D

---

---

SHUTDOWN

/SETBACK

FOR ALL CIRCUITS

120VAC, 6A RESISTIVE

OUTPUT RATINGS:

1A PILOT DUTY, 15A TOTAL

115VAC 60Hz , 30VA MAX

INPUT RATINGS:

USE COPPER WIRE,
CLASS 1 WIRE ONLY.

ENCLOSED

ENERGY

MANAGEMENT

EQUIPMENT

LISTED

99RA

CAUTION: RISK OF ELECTRIC SHOCK

More than one disconnect switch may be required
to de-energize the equipment before servicing.

Boiler 1

Boiler 2

Boiler 3

Boiler 4

Boiler 1

Boiler 2

Boiler 3

Boiler 4

Voltage

Signal Outputs

Out

door S

ensor

S

y

st

em S

ensor

P

ro

v

e Jumper

D

o

Not r

emo

v

e

BMC

SYSTEM

A

B

C

D

Full Modulation Sequencing Control

1

2

RUN

PROGRAM

DO NOT APPLY ANY VOLTAGE

TO INPUT TERMINALS

3

4

5

6

7

8

9 10 11 12

13

15

14

17

16

18

22

20

19

21

24

23

29

25

27

26

28

32

30 31

L N

-

+

+

T

T

O

O

RS-485

mA

GND

VLT

SYS

A

B

C

D

PWR

CUR / VLT

A

-

+

+

mA

GND

VLT

-

+

+

mA

GND

VLT

-

+

+

mA

GND

VLT

+

mA

TEMP

OUTDOOR

O

O

TEMP

SYSTEM

EXTENSION

MODULE

CUR / VLT

B

CUR / VLT

C

CUR / VLT

D

---

---

SHUTDOWN

/SETBACK

FOR ALL CIRCUITS

120VAC, 6A RESISTIVE

OUTPUT RATINGS:

1A PILOT DUTY, 15A TOTAL

115VAC 60Hz , 30VA MAX

INPUT RATINGS:

USE COPPER WIRE,
CLASS 1 WIRE ONLY.

ENCLOSED

ENERGY

MANAGEMENT

EQUIPMENT

LISTED

99RA

CAUTION: RISK OF ELECTRIC SHOCK

More than one disconnect switch may be required
to de-energize the equipment before servicing.

SYSTEM
PROVE

/TSTAT

SYSTEM
PROVE

/TSTAT

L

N

S

y

st

em P

ump

L

N

C

US

L

N

S

y

st

em P

ump

L

N

C

US

4-20mA Modulating

Outputs

Voltage Modulating

Outputs