Drive the digital output, Query status of the digital input – Vivotek IP7130 User Manual
Page 115

VIVOTEK - A Leading Provider of Multimedia Communication Solutions
User's Manual - 115
unit
string[32]
6/6
Organizational unit name in the certificate
information.
commonname
string[64]
6/6
Common name in the certificate information.
validdays
0 ~ 9999
6/6
Valid period for the certification.
Drive the Digital Output
Note: This request requires Viewer privileges.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/dido/setdo.cgi?do1=
[&do3=
Where state is 0 or 1; “0” means inactive or normal state, while “1” means active or triggered state.
PARAMETER
VALUE
DESCRIPTION
0 – Inactive, normal state
do
0, 1
1 – Active, triggered state
return
Redirect to the page
assigned. The
path according to the current path. If you omit this parameter, it
will redirect to an empty page.
Example: Drive the digital output 1 to triggered state and redirect to an empty page.
http://myserver/cgi-bin/dido/setdo.cgi?do1=1
Query Status of the Digital Input
Note: This request requires Viewer privileges.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/dido/getdi.cgi?[di0][&di1][&di2][&di3]
If no parameter is specified, all of the digital input statuses will be returned.