beautypg.com

Drive the digital output, Query status of the digital input – Vivotek IP7130 User Manual

Page 115

background image

VIVOTEK - A Leading Provider of Multimedia Communication Solutions

User's Manual - 115

unit

string[32]

6/6

Organizational unit name in the certificate

information.

commonname

string[64]

6/6

Common name in the certificate information.

validdays

0 ~ 9999

6/6

Valid period for the certification.

Drive the Digital Output

Note: This request requires Viewer privileges.

Method: GET/POST

Syntax:

http://<servername>/cgi-bin/dido/setdo.cgi?do1=[&do2=]

[&do3=][&do4=][&return=]

Where state is 0 or 1; “0” means inactive or normal state, while “1” means active or triggered state.

PARAMETER

VALUE

DESCRIPTION

0 – Inactive, normal state

do

0, 1

1 – Active, triggered state

return

Redirect to the page after the parameter is

assigned. The can be a full URL path or relative

path according to the current path. If you omit this parameter, it

will redirect to an empty page.

Example: Drive the digital output 1 to triggered state and redirect to an empty page.

http://myserver/cgi-bin/dido/setdo.cgi?do1=1

Query Status of the Digital Input

Note: This request requires Viewer privileges.

Method: GET/POST

Syntax:

http://<servername>/cgi-bin/dido/getdi.cgi?[di0][&di1][&di2][&di3]

If no parameter is specified, all of the digital input statuses will be returned.