2 specifications, 1 mechanics, 2 power supply – Viking AD128128M User Manual
Page 6: 3 control
AD6464M / AD128128M
Rev. 5
2 Specifications
2.1 Mechanics
Dimensions:
HxWxD = 220x483x340mm, (19”, 5RU).
Backplane card:
128x128 AES/EBU Digital Audio.
X-point Modules:
64x64 AES/EBU Digital Audio module cards.
System Controller:
1 SysCon card required, must be specified, 1 redundant card
is optional.
GYDA:
2 GYDA-VX cards, both optional.
Safety/Emission standards:
Compliant with CE EN55103-1 and 2, FCC part 15.
2.2 Power Supply
Built-in, redundant power supply. 1 module included, 1 (redundant) optional.
Backplane card:
2x AC-inlets.
Main internal voltage:
36 - 72VDC.
AC Supply voltage range:
90-130VAC / 180-254VAC, switchable, 50-60Hz, 300W.
AC Mains connector:
IEC 320, separate input for each PSU module.
Alarms:
Power failure alarm on relay contact closure, LED in front,
and Open Collector to GYDA-VX.
Alarms connector:
RJ45.
Safety standards:
Compliant with CE EN60950, UL-1950/CSA22.2.
2.3 Control
Standard Features:
Serial ports:
− RS-232/RS-422 for protocol conversion, to VikinX
compact control protocol, or to third party protocols.
(1x per SysCon card).
− RS-232/RS-422 for new router control protocol.
(1x per SysCon card).
Connector: DB9,
female.
Ethernet ports:
− 10/100BaseT Ethernet bus for external router control with
new protocol. (1x per SysCon card).
− 10/100BaseT Ethernet bus for GYDA-VX
(1x per GYDA-VX card).
Connector: RJ45.
Monitored parameters:
− Module temperature.
− Internal module voltages.
Status surveillance:
On each card with LED, and via system controller.
Configuration storage:
Removable compact flash card.
network-electronics.com | 6