beautypg.com

4 cf-card and battery – Viking AD128128M User Manual

Page 13

background image

AD6464M / AD128128M

Rev. 5

The LEDs indicate the following:

Diode

Red LED

Yellow LED

Green LED

No light

Status

Card error.

Not applicable.

Overall status of
the card is OK

Card has no
power, or is not
inserted correctly.

Eth

Not applicable.

Full duplex
connection.

Half duplex
connection.

No Ethernet link
established; check
cable.

Warn

Abnormal situation:
no functional error,
but a situation that
requires attention.
See also chapter 6.

Not applicable.

Normal situation.

Not applicable.

Load

High load on the
µController. May
occur during
system start up and
software
reconfigurations / -
upgrades.

Medium load on
the µController.

Low or normal
load on the
µController.

Not applicable.

Reset button

Figure 9

The reset button on the rear side is used to perform a hard reset of the card. Do not perform
a hard reset, unless the situation demands this. By performing a hard reset, the user looses
control of the router, and will not get control of the router until approximately 20 seconds
after releasing the reset button.

3.4.4 CF-card and battery

All the information regarding the router configuration, as well as information regarding
control panels that are connected to the router, is stored in the Compact Flash card on the
SysCon card.


network-electronics.com | 13

This manual is related to the following products: