4 service switches and reset button – Viking AD128128M User Manual
Page 17
AD6464M / AD128128M
Rev. 5
3.6.4 Service switches and Reset button
There are two slide-switches and one push-button switch on the card, as shown in the figure
below.
Reset button Service switches
Figure 15
The push-button switch is the RESET switch. When this button is pushed and released, the
µController of the X point card resets and restarts its operation with its default settings, or
the settings stored in EEPROM.
The slide switch closest to the front of the X point card (SW2): This switch must always stay in
the right position, as seen from the card front. The switch is for factory use only.
The slide switch furthest from the front of the X point card (SW4): This switch must always be
in the left position, as seen from the card front. The switch is for factory use only.
network-electronics.com | 17