beautypg.com

Leveling/adjustments/alignment, Anti-tip device installation, Warning – Viking F20508 User Manual

Page 9: Tipping hazard

background image

17

1

(A)

(A)

2

(A

)

(A)

+1

/2

+1/2”

(1.

3 c

m)

(1.3 cm)

(A

)

+1

/2

(1.

3 c

m)

3-5

/8”

3-5/8”

(9.2

cm

)

(9.2 cm)

3-5

/8”

(9.2

cm

)

Measure from floor to bottom

of the anit-tip opening located on the back of range.

This will be measurement (A).

Locate anti-tip bracket on rear wall with the top left corner at

measurement (A) plus 1/2” (1.3 cm) from the floor and 3-5/8” (9.2 cm)

from where the right side of range (facing range) is to be located.

3

Mark and drill holes where bracket

will be located.

7

Set the high corner of range so that the top of side trim is

3/8” (0.95 cm) above countertop. Level range to high corner.

Anti-tip Device Installation

16

1

2

Measure the four corners in cutout area to

verify if flooring is level.

For uneven or sloped floors, level unit with

metal shims only, as the adjustment required may

exceed the thread available in the leg.

3

3/

8”

3/8”

(0.

95

cm

)

(0.95 cm)

3/

8”

(0.

95

cm

)

4

Move unit into opening.

Leveling/Adjustments/Alignment

5

Check that unit is level side to

side and front to back. Side trim of the high corner

must be 3/8” (0.95 cm) above countertop.

If leveling is required, move unit out of opening.

6

1

2

1

Lift unit and prop on wood blocks.

WARNING

Tipping hazard.

To reduce the risk of the appliance

tipping, it must be secured by a

properly installed anti-tip bracket(s).

To make sure the bracket has been

installed properly, look behind the

range with a flashlight to verify

proper installation engaged in the

rear top left corner of the range.

• THIS RANGE CAN TIP.

• INJURIES TO PERSONS CAN RESULT.

• INSTALL ANTI-TIP DEVICE PACKED

WITH RANGE.

• SEE INSTALLATION INSTRUCTIONS.