Other Settings

• Priority On: While scanning a conventional system,

the scanner interrupts every 2 seconds and checks
the priority channels in each unlocked conventional
system. Priority channels in lower priority key num-
bered systems (starting from 1) have highest priority.
Pri

appears when you select this mode.

• Priority Plus: The scanner only scans priority

channels in unlocked conventional systems.
Pri

flashes when you select this mode.

Other Settings

Using the Backlight

Set Backlight

E

10 sec

The backlight stays on for 10 seconds after

you press

.

30 sec

The backlight stays on for 30 seconds after

you press

.

Squelch

The backlight turns on when the squelch

opens then stays on for 5 seconds.

Keypress

The backlight turns on when any key is

pressed then stays on for 10 seconds.

Infinite

The backlight turns on when you press

then stays on until you press

again.

Pressing any key while the backlight is on extends the
backlight period. Pressing

while the backlight is on

turns off the backlight.

Initializing the Scanner’s Memory

To initialize the scanner’s memory, turn off the scanner.
Then, press 2, 9, and Hold while turning it on.

Important! This deletes all preprogrammed data.
You cannot restore preprogrammed data that has
been deleted.