Univex 5100-02-IT User Manual
Page 32
Model 5100-02-IT Combustible Gas Sensor Module
Page: 30
Baud:
38400 (Adjustable 2400 to 38400 baud)
Parity: None
Stop
bit:
1
Data
bits:
8
Flow
Control:
None
Memory map:
Appendix H
Warranty:
Limited warranty:
2 years
Specifications subject to change without notice
8.2
APPENDIX B: MODEL NUMBERS, PARTS LIST & PARAMETERS
Sensor Module
Model Enclosure Relay/Connection Protection Remote
5100-02-IT
-
XX -
XX -
XX -
X
-
X
- A1 = AL ¾” NPT
- 01 = No Relays
- 00 = Standard - 0 = Standard
- 0 = None
- A2 = AL M20 x 1.5
- 02 = Relays
- 2 = Conformal - 1 = Remote
- S1 = SS ¾” NPT
- 05 = HART Option
Transmitter Sensor
- S2 = SS M20 x 1.5
Options
5311-00 Rainshield
5311-02
Rainshield with calibration port
Calibration Items
1250-01
Gas Sensor Calibrator Kit
1256-01
Regulator Type A Calibrator
1260-00
Gas Cylinder – Air (Type A), 105 liters
1260-02
Gas Cylinder – Methane 50% LEL, (type A), 105 liters
1260-42
Gas Cylinder - Hydrogen, 50% LEL, (Type A), 105 liters
5358-01
Calibration Adapter - Direct, Standard
5358-50
Calibration/Configuration Magnetic Tool
5360-00
Remote Calibration Fitting
Spare Parts
SPL21813
Transmitter for 5100-02-IT
5200-02-IT-AL
Sensor Assy for 5100-02-IT, AL
5200-02-IT-SS
Sensor Assy for 5100-02-IT, SS
SPL21810
Enclosure, Transmitter, AL
SPL21823
Enclosure, Transmitter, SS
SPL21825
Termination Board no Relays
SPL21829
Termination Board with Relays
SPL21876
HART Termination Board
Factory Default Settings
Output = 3-wire 4-20mA source
Range = 0-100% LEL
Warning = 20% LEL
Alarm = 60% LEL
Calibration = 50% LEL Methane
Modbus = 2-wire Half Duplex at 38,400 BAUD