3.
Remove 12 screws and back panel.
4.
Check that the clamps and hose connections are tight at the fol-
lowing areas:
• Discharge tube (A)
• Drain tube (B)
• Vent tube (C)
5.
Place a suitable container beneath the pump’s discharge tube.
(The bucket must be able to hold a minimum of one gallon.)
Back panel serves as a guard. DO NOT put your hands
inside the ice maker cabinet or attempt to touch any com-
ponents except the discharge tube during testing. Failure
to follow this warning could result in serious personal
injury or death.
6.
Plug the ice maker power cord into a properly grounded, polarized
electrical outlet.
7.
Verify pump operation by pouring one gallon of water into the ice
storage bin of the ice maker. The pump should energize and
pump the water into the container.
8.
At this time, verify that all tube and clamp connections are tight
and leak free.
9.
Unplug unit power cord from electrical outlet.
10. Leave back panel off for water supply line installation.
11. Continue to the next step in the installation process, SITE
PREPARATION.
!