Warning, Disconnect power to the unit. figure 29 – U-Line CLR2060 User Manual
Page 27
25
The ice cube thickness control is factory set for best overall perfor-
mance. The factory setting is designed to maintain an ice bridge of
approximately 1/16" to 1/8" under normal conditions resulting in a
dimple of approximately 1/4" to 1/2" in depth (see Figure 28). A fuller
cube with less of a dimple results in a thicker ice bridge. As the ice
bridge becomes thicker, the tendency for the cubes to stay together as
a slab increases. A bridge thicker than 1/8" may cause cubes to over-
fill the ice bucket.
Figure 28 – Cube Types
To adjust:
Disconnect power to the ice maker before making
any ice thickness adjustments.
1.
Disconnect power to the unit.
Figure 29
ICE003
ACCESS PANEL SCREWS
I
C
E
O F F
C L N
!
WARNING
GOOD
BRIDGE
TOO THIN
BRIDGE
TOO THICK
DIMPLE
TOO DEEP
LITTLE OR
NO DIMPLE
1/4" TO 1/2"
DIMPLE
1/16" TO 1/8"
ICE BRIDGE
BAD
ICE002
Body_UM.qxd 12/17/04 9:16 AM Page 25