U-Line CLR2060 User Manual
Page 39

37
Problem
Possible Cause
Remedy
Unit runs but
Scale and mineral
Clean unit. See
produces very
buildup in unit.
MAINTENANCE.
little ice.
Inadequate airflow at
Remove items blocking
(continued)
the front of the unit.
airflow.
Ice is slow to
Ice-making system
Run unit through
release or does
is dirty.
automatic clean cycle.
not release from
See MAINTENANCE.
the evaporator.
Unit is not level.
See LEVELING THE
UNIT.
Low air temperature
Surrounding air
around unit.
temperature must be
at least 50°F (10°C).
Poor ice quality.
Poor incoming water
Consult a qualified
(soft or unclear)
quality.
plumber to test the
water quality and
recommend appropriate
treatment.
Ice-making system is
Run unit through
dirty.
automatic clean cycle.
See MAINTENANCE.
Unit produces
Low water level.
Check to see that
shallow or
overflow tube is fully
incomplete cubes,
seated.
or the ice fill
pattern on the
Hot incoming water.
Connect the unit to a
evaporator is
cold water supply.
incomplete.
See INSTALLATION.
Incorrect incoming
Water pressure must
water pressure.
be 20-120 psi.
Unit is not level.
See LEVELING THE
UNIT.
Body_UM.qxd 12/17/04 9:16 AM Page 37