beautypg.com

5. outdoor control board, Hws-802h-e – Toshiba HWS-802XWHT6-E User Manual

Page 31

background image

30

Toshiba

6-5. Outdoor Control Board

HWS-802H-E

Electrolytic capacitors

Reactor connection connector

Compressor output terminals

CN202
CN201
CN200

Fan motor output
CN300 (White)

Case thermostat connector

CN609(Blue)

4-way valve connector

CN701(White)

Compressor ON

output connector

CN704(Blue)

Heater output connector

CN703(Grey)

External input connector

CN610(Yellow)

Special operation switches

SW801
SW804

Display change-over switches

SW800
SW803

Temperature sensor connectors

TL CN604(White)

TD CN603(White)

TO CN602(Yellow)

TE CN601(White)
TS CN600(White)

Alive, error display LEDs

D800 804(Yellow)

D805(Green)

PMV connector

CN710 (White)

Initialization switch

SW802

Power circuit protection
fuse
F01 (250V, 25A)

Connecting cable connector

CN04(White)

Connecting cable protection fuse

F03 (250 V, 10 A)

Earth lead wire

P09 (Black)

Power supply connection lead
wires
P01(Red)
P02(White)

Hydro-outdoor communication signal LEDs

D503 (Green, Outdoor => Hydro)

D502 (Amber, Hydro => Outdoor)

4-way valve protection
fuse
F700 (250 V, 3.15 A,
plastic case)

Power circuit protection

fuse

F100 (250 V, 3.15 A,

plastic case)

+00A09-002_01EN_SVM_ALL_Air_to_Water.book Page 30 Monday, October 5, 2009 2:09 PM