Adjustments

Technical Manual LDK 20(S) - Studio Camera

4-49

Encoder Board NTSC

Burst timing
23. Observe waveform monitor or oscilloscope and adjust the burst position so that it is 5.3µS from the leading

edge of the line synchronisation.

Measure at:

Adjust with:

Required result:

Correct:

CVBS out

ZR209

5.3µS

0%

10

90

100

50mV

1µS

t+5.3µs 178kHz

5.3µs

Genlock free-running preset
24. Remove genlock signal from camera.
25. Turn lock range potentiometer ZR215 fully counterclockwise.
26. Observe colour monitor, waveform monitor or vectorscope and adjust oscillator preset potentiometer for

minimum free-running.

Measure at:

Adjust with:

Required result:

CVBS out

ZR216

Minimum free-

running speed

I/Q bar amplitude
27. Adjust the I and Q bars for an amplitude of 286mV (40 IRE).

Measure at:

Adjust with:

Required result:

Correct:

CVBS out

ZR207

I-bar amplitude

20

40

R

60

80

0.7

100

120

20

43

0.3

g

YL

MG

cy

b

B

yl

G

r

CY

mg

75

100

U

V

0

0

5

-5

%

VOLT

CVBS out

ZR201

Q-bar amplitude

I bar Q bar

28. Switch off power and return encoder board to its position in the camera.