beautypg.com

Encoder board ntsc, Measure at: adjust with: required result: correct, 40 ire) – Technicolor - Thomson STUDIO CAMERA LDK 20(S) User Manual

Page 73

background image

Adjustments

Technical Manual LDK 20(S) - Studio Camera

4-47

Encoder Board NTSC

I / Q 90° phase
16. Connect MP7 on the encoder board to ground.
17. With the phase potentiometer on the vectorscope, place the I vectors along the I-axis of the graticule.

Measure at:

Adjust with:

Required result:

Correct:

20

40

R

60

80

12.5%

100

120

20

40

100%

YL

MG

B

G

CY

75 100

I

Q

75%

0

5

-5

IRE

0%

18. On the encoder board disconnect MP7 from ground and connect MP8 to ground.
19. Adjust the phase of the Q vectors with L8 so that they lie along the Q-axis of the graticule.

Measure at:

Adjust with:

Required result:

Correct:

CVBS out

L8

20

40

R

60

80

12.5%

100

120

20

40

100%

YL

MG

B

G

CY

75 100

I

Q

75%

0

5

-5

IRE

0%

20. Repeat steps 16. to 20. until the best results are obtained.

BURST ADJUSTMENTS

Burst phase
21. Adjust the burst phase potentiometer to place the burst vector along the horizontal axis

Measure at:

Adjust with:

Required result:

Correct:

CVBS out

ZR211

20

40

R

60

80

12.5%

100

120

20

40

100%

YL

MG

B

G

CY

75 100

I

Q

75%

0

5

-5

IRE

0%

Burst amplitude
22. Adjust the burst amplitude potentiometer to obtain a burst amplitude of 286mV (40 IRE).

Measure at:

Adjust with:

Required result:

Correct:

CVBS out

ZR210

286mV

0%

10

90

100

0.1V

2µS

VA+286mV