Adjustments

Technical Manual LDK 20(S) - Studio Camera

4-41

Encoder Board PAL

Burst amplitude
19. Adjust the burst amplitude potentiometer to obtain a burst amplitude of 300mV.

Measure at:

Adjust with:

Required result:

Correct:

CVBS out

ZR210

300mV

0%

10

90

100

0.1V

2µS

VA+300mV

Burst timing
20. Observe waveform monitor or oscilloscope and adjust the burst position so that it is 5.6µS from the leading

edge of the line synchronisation.

Measure at:

Adjust with:

Required result:

Correct:

CVBS out

ZR209

0%

10

90

100

50mV

1µS

t+5.6µs 178kHz

Genlock free-running preset
21. Remove genlock signal from camera.
22. Turn lock range potentiometer ZR215 fully counterclockwise.
23. Observe colour monitor, waveform monitor or vectorscope and adjust oscillator preset potentiometer.

Measure at:

Adjust with:

Required result:

CVBS out

ZR216

Minimum freerunning speed

Sc-H phase relationship
24. Switch vectorscope to internal synchronisation.
25. Adjust Sc-H phase potentiometer for 180°.

Measure at:

Adjust with:

Required result:

Correct:

CVBS out

ZR217

20

40

R

60

80

0.7

100

120

20

43

0.3

g

YL

MG

cy

b

B

yl

G

r

CY

mg

75

100

U

V

0

0

5

-5

%

VOLT

26. Switch off power and return encoder board to its position in the camera.