White pulse amplitude
17. Connect camera to a base station and switch to Triax mode.
18. Adjust the white pulse in line 10 (PAL), in line 13 (NTSC) for the R-Mux output.

Measure at:

Adjust with:

Required result:

Correct:

X17A-27

ZR201

700mV

0%

10

90

100

19. Adjust the white pulse in line 10 (PAL), in line 13 (NTSC) for the G-Mux output.

Measure at:

Adjust with:

Required result:

Correct:

X17A-19

ZR401

700mV

0%

10

90

100

20. Adjust the white pulse in line 11 (PAL), in line 14 (NTSC) for the B-Mux output.

Measure at:

Adjust with:

Required result:

Correct:

X17A-23

ZR601

700mV

0%

10

90

100

21. Set up camera in the stand-alone mode again.

Monitoring camera output
22. Use the controls at the rear panel of the camera to select the Y signal for the monitoring output by navigating

through the menu system.

23. Connect oscilloscope terminated with 75 Ohm to the VF output of the camera.
24. Adjust the amplitude of the VF output signal.

Measure at:

Adjust with:

Required result:

Correct:

VF output

ZR111

PAL 700mV

0%

10

90

100

0.2V

10µS

VB+700mV

NTSC 714mV

(100IRE)