Adjustments

Technical Manual LDK 20(S) - Studio Camera

4-33

Sync/Shading Board

24. On Video Processor 1 Board adjust the vertical sawtooth potentiometer for no sawtooth information. (Select

the viewfinder R, G and B output signals in the VF/Lens - VF Inst menu.)

Measure at:

Adjust with:

Required result:

VF out R

ZR214

Video signal as flat

VF out G

ZR414

as possible in

VF out B

ZR614

vertical direction.

Video Processor 1 Board

Black Offset
25. In the Install/Gain menu set the gain for + to 12dB and for Max gain (the standard values are 6dB and 12dB).
26. While switching between 0dB gain and Max gain, adjust black level during the active line to the same as the

clamp level.

Measure at:

Adjust with:

Required result:

Correct:

Incorrect:

X56-14(R)

ZR208 (R)

0mV (R)

0%

10

90

100

10mV

10µS

0%

10

90

100

10mV

10µS

X56-8(G)

ZR408 (G)

0mV (G)

X56-20(B)

ZR608 (B)

0mV (B)

Note:

When the standard file is recalled the black levels are set as follows: Master=50, R=50, G=50, B=50.

Sync/Shading Board

27. In the Install/Gain menu reset the gain for + to 6dB and for ++ to 12dB.
28. Switch to Aspect Ratio 16:9 and check black shading.
29. Remove sync/shading board and Video Processor 1 board from service extender and return it to its position

in the camera.

White shading exposure
30. Mount lens on camera. Switch on power.

Recall Factory Standard File on MCP or OCP or Camera.
On MCP set:

OPERATE MENU

Knee

:

Off

Gamma

:

Lin.

Auto Iris

:

Off

Exposure

:

1/1000

SETUP 5 MENU

Matrix

:

1:1

MAINT 1 MENU

Wh. shading :

On

31. Point camera at a white uniformly illuminated test chart (preferable a spherical illuminator). Set diaphragm

to F5.6 and zoom for no vignetting. Adjust illumination for an 80% video level.

32. Select the red viewfinder signal.
33. Observe the CVBS output on the waveform monitor and adjust the frame flicker potentiometer for minimum

flicker between odd and even fields.

Measure at:

Adjust with:

Required result:

CVBS out

R300

Minimum variation

between fields