beautypg.com

Texas Memory Systems RamSan-325/325c User Manual

Page 120

background image

RamSan-325/325c User’s Manual

- 116 -

Name fan-state-notif
Description
The fan state has changed
Includes

Message
Fan State:

-1 notImplemented This indicates there may be an SNMP reporting

problem

0 noState

N/A

1 error

One or more fan channels have stopped;

temperature warnings that will cause the system

to shutdown are imminent.

2 warn

Single fans in one or more fan channels have
stopped or are running slowly. There is no

immediate danger, but the fans may need to be

serviced.

3 good

All fans are working properly.

4 warnHigh

One or more fans are spinning too fast. The

system is in no immediate danger but may need
to be serviced.

5 errorHigh

N/A

6 noDevice

N/A

7 notMonitored

Fan monitoring has been turned off to suppress

warnings.


Name disk-state-notif
Description
The disk state has changed
Includes

Message

Device Number
Disk State:

-1 notImplemented This indicates there may be an SNMP reporting

problem

0 noState

N/A

1 error

N/A

2 warn

N/A

3 good

The disk is working properly

4 warnHigh

The disk is rebuilding.

5 errorHigh

The disk has failed, or is missing from the system.

6 noDevice

N/A

7 notMonitored

Monitoring has been turned off to suppress
warnings.