Notes to users, Step 1: safety approval – Toshiba Strata CT Digital Business Telephone Solutions User Manual
Page 33
Strata CT ACD Supervisor November 2001
25
Notes to Users
Step 1: Safety Approval
Toshiba Information System (U.K.) Ltd declare that the Strata CT complies with the EEC’s LVD
directive, (Directive No. 73/23/EEC). The product has been assessed and found to comply with
EN60950:2000.
The notes listed below form part of the products compliance with the aforementioned European
Norm.
1-1. The system, PCOU/RCOU/RCOS unit, must be earthed. The earth connection must be
hardwired to a main distribution point. The main cabinet must be earthed.
1-2. Table A1 below identifies and classifies the ports available on the system:
Table A1
Type of Circuit
(EN60950
Classification)
Port Location
Port Description
SELV
Power Supply
BPSU672F
For connection of external 24 volt batteries.
SELV
Processor Boards:
B1CU1F, B2CAU1A,
B3CAU1A, B5CAU1A
For connection of external Music-on-Hold source
SELV
PDKU2A
For connection of Toshiba propriety terminals.
SELV
PEKU2F
For connection of Toshiba Visually Handicapped Console terminals.
TNV3
RSTU1F
For connection of approved 2 wire devices.
TNV3
RSTU3F
For connection of approved 2 wire devices.
TNV3
PCOU2F/PCOUS2F
For connection to PTO provided Loop Call Unguarded Clear
exchange lines.
TNV3
RCOU3F/RCOS3F
For connection to PTO provided Loop Call Unguarded Clear
exchange lines.