TOSLINE-S20 Active Star Coupler (ASC25) Instruction Manual

6F3B0360

TOSLINE S20

33

(3)

Fold the tension member, and insert the collar through the jacket of optical fiber core wire

until the collar went under the cord housing. The collar shall be exposed from the edge of

housing removal by 1 mm or less.

Housing

Collar

Jacket

Tension member
is divided to two
equal portions.

Housing

Collar

Jacket

max. 1 mm

Figure 9.11 Collar insertion

Figure 9.12 Protrusion of collar

(4)

Using the jacket remover (use the hole at 0.5 side of label indication), remove the cover

(semi-transparent) of core wire of the optical fiber.

Housing

Clad

Core cover

max. 2 mm

Figure 9.13 Residual length of core cover