12

ASC25 Instruction Manual

(2)

Functional specifications

The functional specifications of the Active Star Coupler are listed below.

Item

Description

Number of connectable
stations

Max. 10

for FC Type
connector

Silica glass optical fiber cable (JIS C6820)
GI 50/125

µ

m (core dia./clad dia.)

Applied optical fiber

for F07 Type
connector

H-PCF (hard clad silica glass core fiber) cable
SI Model 200/230

µ

m (core dia./clad dia.)

Transmission distance

Station to Star Coupler

: Max. 1 km

Star Coupler to Star Coupler : Max. 1 km
Total system

: Max. 10 km

Number of daisy-chain
connection of Star
Couplers

Max. 9

Connectable apparatus

TOSLINE-S20 fiber optic network stations.

HEALTHY contact (Relay
contact)

"ON" during normal operation
Contact rating
Voltage: 250 V AC

Current: max. 1 A

Voltage: 24 V DC

Current: max. 1 A

Voltage: 5 V AC/DC

Current: min. 10 mA