ASC25 Instruction Manual

6.6

Optical connector

For the transmission cables of the Active Star Coupler, the optical fiber cables (cords) are

used.

(1)

Position and name of optical connector

The Active Star Coupler has ten optical connector connection ports, CH1 through CH10.

They are positioned on the front panel of the unit: CH1 and CH10 are FC Type connectors, and

CH2 through CH9 are F07 Type connectors.

(2)

Connection cable

for FC Type: (CH1 and CH10)

Optical fiber cable:

Silica Glass GI optical fiber cable (core diameter 50

µ

m, clad

diameter 125

µ

m)

for F07 Type: (CH2 through CH9)

Optical fiber cable:

H-PCF (hard clad Silica Glass SI optical fiber cable (core

diameter 200

µ

m, clad diameter 230

µ

m)

(3)

Connection of cables

Connection is made between FC Type connector and FC Type connector, and between

F07 Type connector and F07 Type connector.

For more detail, refer to "9. Installation and wiring".

(Note) Sinse all ports have no priority among them, arbitrary one may be used. Nevertheless,

when the daisy-chain connection between ASC25s is done, use CH1 and CH10 (FC

Type). (Although CH2 through CH9 can establish the daisy-chain connection between

ASC25s without raising functional problems, the FC Type connector has a function of

preventive means to single-wire breaking and is able to function the preventive means to

single-wire breaking between ASC25s, so that we recommend the use of CH1 and CH10.