Connecting the Alarm Terminals

i

Connecting the ALARM IN/OUT terminals

• When the alarm switch is ON, alarm recording starts. It is possible to confirm the warning from outside by connecting the

switching input of external interface devices such as alarm lamp or alarm buzzer to the alarm output. Please do not use the
alarm output for power source to any of external devices.

i

Connecting alarm reset input

To GND

To alarm out

Warning

External

interface

Alarm lamp or alarm buzzer

To alarm in

Alarm switch

To GND

To alarm reset

Alarm reset switch

• When the alarm switch is ON, alarm recording starts. However, when a closure is applied across the ALARM RESET and

GND terminals, the alarm record condition resets and the VCR returns to the original record mode it was in before the alarm
condition occurred.

Note:

i

When simultaneously connecting alarm input and alarm reset input, be sure to carefully check the voltage levels.