beautypg.com

Installation procedure – Toshiba TEC EM1-31071GE User Manual

Page 22

background image

7-1

7. INSTALLATION PROCEDURE

7. INSTALLATION PROCEDURE

Remote Display

CAUTION: Never place the scale upside down. Doing so will cause a malfusction.

1.

To install the remote display, insert the two screws on the bottom of the remote pipe into
the holes provided on the scale base.

2.

Connect the connectors, pull down the connector cover, and install the remote blind plate.

Then tighten the screws to secure the remote display.

3.

Remove the tape from the remote packing and remote cap and lower to fit them to the
scale.

7. INSTALLATION PROCEDURE

Remote Display

Remote Pipe

Remote Cap

Remote Packing

Tape

Hole

Screw

Screw

Remote Blind Plate

Connector

Connector

Connector Cover

WARNING!

Be sure to cover the connectors with the connector cover because of high voltage and
current. If the connectors are exposed to water, a leakage may result.