Jbw50w type – TDK J Series JBW User Manual
Page 8

(8/30)
004-02 / 20070523 / ea122_jbw.fm
• All specifications are subject to change without notice.
JBW50W Type
SPECIFICATIONS AND STANDARDS
∗1
Current rating(maximum output current) is determined for –10 to +50°C. Derating is required when used outside this temperature range.
∗2
Please note that the deterioration of parts is occasionally caused when operating for a long time(over 10 minutes) with the voltage below the range of the
input voltage.
• Optional input, output cable kits are available at a separate price.
Part No.
JBW05-10R
JBW12-4R3
JBW15-3R5
JBW24-2R1
Rated output voltage and current
∗1
5V • 10A
12V • 4.3A
15V • 3.5A
24V • 2.1A
Maximum output power
W
50
51.6
52.5
50.4
Input conditions
Input voltage Eac/Edc
∗2
V
85 to 265[Rating: 100 to 240]/120 to 375
Input frequency
Hz
47 to 66[Rating: 50 to 60](Single phase)
Input current
A
0.7typ./0.88max. [AC.100V]0.35typ./0.5max.[AC.240V]
Fuse rating
A
3.15[AC.250V, built-in]
Surge current
A
15typ.(30max.)[AC.100V]40typ.(60max.)[AC.240V] cold start
Leakage current
mA
0.35typ./0.75max.[AC.100V, 60Hz]0.5typ./0.75max.[AC.240V, 60Hz]
Power factor
0.99typ./0.93typ.[AC.100/240V]
Efficiency
%
77typ.[AC.100V]
80typ.[AC.100V]
80typ.[AC.100V]
81typ.[AC.100V]
%
79typ.[AC.240V]
81typ.[AC.240V]
81typ.[AC.240V]
83typ.[AC.240V]
Output characteristics
Output voltage Edc
V
5
12
15
24
Voltage variable range Edc
V
4.5 to 5.5
10.8 to 13.2
13.5 to 16.5
21.6 to 26.4
Maximum output current
A
10
4.3
3.5
2.1
Minimum output current
A
0
0
0
0
Overvoltage threshold Edc
V
5.75 to 6.9
13.8 to 16.8
17.2 to 21
27.6 to 33.6
Overcurrent threshold
A
10.5min.
5.4min.
4.4min.
2.7min.
Voltage
stability
Source effect
%
0.4max.[Within the input voltage range]
Load effect
%
0.8max.[0 to 100% load]
Temperature effect
%
1max.[Ambient temperature: –10 to +50°C]
Drift(Time effect)
%
0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
Recovery
%
±4max.[50 to 100% sudden load change]
Ripple Ep-p
mV
80max.
120max.
120max.
120max.
Ripple noise Ep-p
mV
120max.
150max.
150max.
150max.
Start up time
ms
500max.(400typ.)/500max.(400typ.) [AC.100/240V]
Hold up time
ms
20typ./20typ. [AC.100/240V]
Auxiliary functions
Indicator display
No
Overvoltage protection
Voltage shut-down type.
Overcurrent protection
Rectangular type, automatic recovery.
Remote ON-OFF
No
Remote sensing
No
Parallel operation
Impossible
Series operation
Possible
Output voltage external variable function
No
Standards
Safety standards
UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved.
Noise terminal voltage
FCC-B, VCCI-B, EN55011-B, EN55022-B meet.
Input harmonics current requirement
EN61000-3-2 meet.
Constructions
External dimensions
mm
26
Ч 55Ч 190[HЧ WЧ L]
Weight
g
220max.
Mounting method
Can be attached to 1 side.
Case material
No(PWB Material: CEM3)