beautypg.com

Jbw75w type – TDK J Series JBW User Manual

Page 10

background image

(10/30)

004-02 / 20070523 / ea122_jbw.fm

• All specifications are subject to change without notice.

JBW75W Type

SPECIFICATIONS AND STANDARDS

Part No.

JBW05-15R

JBW12-6R3

JBW15-5R0

JBW24-3R2

Rated output voltage and current

5V • 15A

12V • 6.3A

15V • 5.0A

24V • 3.2A

Maximum output power

W

75

75.6

75

76.8

Input conditions
Input voltage Eac/Edc

V

85 to 265[Rating: 100-240]/120 to 370

Input frequency

Hz

47 to 66

Input current

A

1.6/0.8max.[100-240V]

Fuse rating

A

3.15

Surge current

A

30/60max.[100-240V]

Leakage current

mA

0.75/0.75max.[AC.100V(DENAN)/240V(UL, IEC)]

Power factor

0.99/0.95typ.[100-240V]

Efficiency

%

75/77typ.
[100-240V]

78/80typ.
[100-240V]

79/81typ.
[100-240V]

82/84typ.
[100-240V]

Output characteristics
Output voltage Edc

V

5

12

15

24

Voltage variable range Edc

V

4.5 to 5.5

10.8 to 13.2

13.5 to 16.5

21.6 to 26.4

Maximum output current

A

15

6.3

5.0

3.2(Peak4.2)

Overvoltage threshold Edc

V

5.75 to 6.9

13.8 to 16.8

17.2 to 21

27.6 to 33.6

Overcurrent threshold

A

15.8min.

6.6min.

5.2min.

4.4min.

Voltage
stability

Source effect

%

0.4max.[Within the input voltage range]

Load effect

%

0.8max.[0 to 100% load]

Temperature effect

%

1max.[Ambient temperature: –10 to +60°C]

Drift(Time effect)

%

0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]

Recovery

%

±4max.[50 to 100% sudden load change]

Ripple Ep-p

mV

80

120

120

120

Ripple noise Ep-p

mV

120

150

150

150

Start up time

ms

500max.(400typ.)/250max.(200typ.)[AC.100/240V]

Hold up time

ms

20typ.[100-240V]

Auxiliary functions
Indicator display

No

Overvoltage protection

Voltage shut-down type(Latch).

Overcurrent protection

Rectangular type, automatic recovery.

Remote ON-OFF

No

Remote sensing

No

Standards
Safety standards

UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved.

Noise terminal voltage

FCC-B, VCCI-B, EN55011-B, EN55022-B meet.

Input harmonics current requirement

EN61000-3-2

CE marking

Planned compliance.

Constructions
External dimensions

mm

32

Ч 55Ч 222[HЧ WЧ L]

Weight

g

290max.

Mounting method

Can be attached to 1 side.

Case material

CEM3