beautypg.com

Jbw30w type – TDK J Series JBW User Manual

Page 6

background image

(6/30)

004-02 / 20070523 / ea122_jbw.fm

• All specifications are subject to change without notice.

JBW30W Type

SPECIFICATIONS AND STANDARDS

Current rating(maximum output current) is determined for –10 to +50°C. Derating is required when used outside this temperature range.

• Optional input, output cable kits are available at a separate price.

Part No.

JBW05-6R0

JBW12-2R5

JBW15-2R0

JAW24-1R3

Rated output voltage and current

5V • 6A

12V • 2.5A

15V • 2A

24V • 1.3A

Maximum output power

W

30

30

30

31.2

Input conditions
Input voltage Eac/Edc

V

85 to 265[Rating: 100 to 240]/110 to 370

Input frequency

Hz

47 to 440[Rating: 50 to 60](Single phase)

Input current

A

0.65typ./0.86max.[AC.100V]0.35typ./0.48max.[AC.240V]

Fuse rating

A

2[AC.250V, built-in]

Surge current

A

15typ./30max.[AC.100V]30typ./60max.[AC.240V] 1st surge current, cold start, reset after 1s minimum.

Leakage current

mA

0.35typ./0.75max.[AC.100V, 60Hz]0.5typ./0.75max.[AC.240V, 60Hz]

Power factor

0.6typ./0.45typ.[AC.100/240V]

Efficiency

%

75typ.[AC.100V]

78typ.[AC.100V]

79typ.[AC.100V]

80typ.[AC.100V]

%

77typ.[AC.240V]

79typ.[AC.240V]

80typ.[AC.240V]

81typ.[AC.240V]

Output characteristics
Output voltage Edc

V

5

12

15

24

Voltage variable range Edc

V

Fixed

Fixed

Fixed

Fixed

Maximum output current

A

6

2.5

2

1.3

Minimum output current

A

0

0

0

0

Overvoltage threshold Edc

V

5.6min.

13.3min.

16.6min.

26.5min.

Overcurrent threshold

A

6.3min.

2.7min.

2.1min.

1.4min.

Voltage
stability

Source effect

%

0.4max.[Within the input voltage range]

Load effect

%

0.8max.[0 to 100% load]

Temperature effect

%

2max.[Ambient temperature: –10 to +50°C]

Drift(Time effect)

%

0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]

Recovery

%

±4max.[50 to 100% sudden load change]

Ripple Ep-p

mV

80max.

120max.

120max.

120max.

Ripple noise Ep-p

mV

120max.

150max.

150max.

150max.

Start up time

ms

650max.(350typ.)/320max.(130typ.)[AC.100/240V]

Hold up time

ms

20typ./160typ.[AC.100/240V]

Auxiliary functions
Indicator display

No

Overvoltage protection

Voltage shut-down type.

Overcurrent protection

Rectangular type(Winker operation), automatic recovery.

Remote ON-OFF

No

Remote sensing

No

Parallel operation

Impossible

Series operation

Impossible

Output voltage external variable function

No

Standards
Safety standards

UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved.

Noise terminal voltage

FCC-B, VCCI-B, EN55011-B, EN55022-B meet.

Input harmonics current requirement

No

Constructions
External dimensions

mm

26

Ч 55Ч 122[HЧ WЧ L]

Weight

g

150max.

Mounting method

Can be attached to 1 side.

Case material

No(PWB Material: CEM3)