beautypg.com

Toshiba VF-nC1 User Manual

Page 66

background image

E6581090

F-2

6

Output frequency [Hz]

Time [sec]

H

Low speed signal output: 4
FM/OUT terminal (H)

FL terminal (H)

ON
OFF

ON
OFF

0

Set frequency

Low speed reverse signal output: 5
FM/OUT terminal (H)

FL terminal (H)

* FM/OUT terminal function selection (HOUN) : 0 (Output frequency)

[Connection diagram]

P15

OUT

Ry

6.1.2 Output of specified speed reach si+gnal (output of arbitrarily set frequency)

H : Speed-reach setting frequency (Hz)

H : Output terminal selection 1 (FM/OUT)
HOUN : FM/OUT terminal functions selection

H : Output terminal selection 3 (FLA, FLB, FLC)

Function

If the output frequency exceeds the H-set frequency

±2.5 Hz, an OFF signal will be put

out.
ڎ

The low speed signal output frequency function is assigned by default to the FM/OUT
terminal.

ڎ

Before using the FM/OUT terminal, you need to make a selection between meter (PWM)
output and open collector output.
To use the FM/OUT terminal as an open collector output terminal, set HOUN to -1 (open
collector output).

ڎ

Signals can be sent to the relay output terminals FLA, FLB and FLC by changing a
parameter setting.

Parameter for specifying a frequency

Title

Function

Adjustment range

Default setting

H

Speed-reach setting frequency
(Hz)

0.0~HJ (Hz)

0.0

 ■

Related parameters

Title

Function

Adjustment range

Default setting

HOUN FM/OUT terminal functions

selection

-1: Open collector output
0: Output frequency
1: Output current
2: Frequency setting
3: Adjustment (current output

fixed at 100%)

4: Adjustment (current output

fixed at 50%)

5: Adjustment (output fixed at

the max frequency)

6: Adjustment (gain display)

0

H

Output terminal selection 1 (FM/OUT) 0~13 (See 6.2.6 for details.)

4

H

Output terminal selection 3 (FL)

0~13 (See 6.2.6 for details.)

10

If using the relay with the rated voltage DC12V of operating
coil, the maximum allowable voltage should be higher than
120% of rated voltage, and the maximum ampere value
should not exceed 50mA.
(Operating coil resistance 250 ~ 800

Ω approx.).