Toshiba VF-nC1 User Manual
Page 122

E6581090
K-10
11
■
Table of input terminal functions 2
Function
No.
Code
Function
Action
29
R+SS4
Combination of reverse run and preset
speed command 4
ON : Simultaneous input of R and SS4
commands
30
F+SS1+AD2
Combination of forward run, preset
speed command 1 and
acceleration/deceleration 2
ON : Simultaneous input of F, SS1 and
AD2 commands
31
R+SS1+AD2
Combination of reverse run, preset
speed command 1 and
acceleration/deceleration 2
ON : Simultaneous input of R, SS1 and
AD2 commands
32
F+SS2+AD2
Combination of forward run, preset
speed command 2 and
acceleration/deceleration 2
ON : Simultaneous input of F, SS2 and
AD2 commands
33
R+SS2+AD2
Combination of reverse run, preset
speed command 2 and
acceleration/deceleration 2
ON : Simultaneous input of R, SS2 and
AD2 commands
34
F+SS3+AD2
Combination of forward run, preset
speed command 3 and
acceleration/deceleration 2
ON : Simultaneous input of F, SS3 and
AD2 commands
35
R+SS3+AD2
Combination of reverse run, preset
speed command 3 and
acceleration/deceleration 2
ON : Simultaneous input of R, SS3 and
AD2 commands
36
F+SS4+AD2
Combination of forward run, preset
speed command 4 and
acceleration/deceleration 2
ON : Simultaneous input of F, SS4 and
AD2 commands
37
R+SS4+AD2
Combination of reverse run, preset
speed command 4 and
acceleration/deceleration 2
ON : Simultaneous input of R, SS4 and
AD2 commands
38
FCHG
Frequency command forced switching
Enabled if HOQF = 4 (selectable
between terminal board and operation
panel/internal potentiometer)
ON : VI terminal
OFF : Internal potentiometer
39
THR2
No.2 thermal switching
ON : No.2 thermal (RV:, H,
H
, H, H)
OFF : No.1 thermal (RV: Setting, XN,
H
, XD, VJT)
40
MCHG
No.2 motor switching
ON : No.2 motor (RV:0, H,
H
, H, H, H,
H
)
OFF : No.1 motor (Pt: Setting, XN,
H
, XD, VJT, CEE,
FGE
)
49
HD
Operation holding
(Stop of 3-wire operation)
ON : F (forward run) / R (reverse run)
held, 3-wire operation
OFF : Slowdown stop
54
FreeRun
Standby (inversion)
ON : Free run
OFF : Standby
55
RSTN
Reset signal (inversion)
OFF to ON: Trip reset
56
F+ST
Combination of forward run and standby
commands
ON : Simultaneous input of F and ST
commands
57
R+ST
Combination of reverse run and standby
commands
ON : Simultaneous input of R and ST
commands
*This function is effective after software version V110.
*