beautypg.com

Fill switch (item 2), Add mix light (item 3), Mix out light (item 4) – Taylor SLUSH 382 User Manual

Page 15: Viscosity control (item 5), Standby switch (optional), Display light switch (item 6) (optional), Push-button switch

background image

11

Models 382/RC25

Important: To the Operator

Fill Switch (Item 2)

The fill switch is located under the control channel. The

“ON” position enables refrigeration when the control

switch is in the “AUTO” position. The “ON” position

enables the fill system to replenish and maintain

product levels in the freezing cylinder and in the

hopper. The “OFF” position terminates the fill function.

The refrigeration system is disabled when the fill

switch is in the “OFF” position.

Add Mix Light (Item 3)

An “ADD MIX” indicating light is located on the front

panel. When the light is lit, it indicates that the mix

supply in the hopper is low and must be replenished.

Mix Out Light (Item 4)

A “MIX OUT” indicating light is located on the front

panel. When the light is lit, it indicates that the hopper

is empty and the mix supply must be replenished.

When the indicator lights, refrigeration is automatically

disabled to prevent component damage. The beater

motor continues to run.

Viscosity Control (Item 5)

The viscosity adjustment screw is located under the

control channel. The viscosity (thickness) of the slush

can be adjusted by turning the adjustment screw

clockwise for a thicker product or counterclockwise for

a thinner product.

Standby Switch (Optional)

The standby switch is located under the control

channel. To maintain a refrigerated product during long

no sale periods, the standby mode will maintain the

product at approximately 38_F to 40 _F (3.3_C to

4.4_C).

To operate the standby mode, place the power switch

in the “AUTO” position. Place the fill switch in the

“FILL” position and the standby switch in the

“STANDBY” position.

To resume normal operation, leave the power switch

in the “AUTO” position and the fill switch in the “FILL”

position. Move the standby switch to the “OFF”

position.

Display Light Switch (Item 6)

(Optional)

The display light switch is located under the control

channel. The left position is “OFF”. The right position

is “ON”, and activates the display light.

Push-Button Switch

If an overload condition occurs, the freezer will

automatically stop operating. To properly reset the

freezer, place the toggle switch in the “OFF” position.

Wait two or three minutes; then press the push-button

switch. Place the power switch in the “WASH” position

and observe the freezer’s performance; place the

power switch in the “AUTO” position.

Note: If the freezer is unplugged from the wall

receptacle, it will be necessary to press the

push-button switch for the freezer to operate once

power is re-established.