Chapter 6 - power and power-up modes, Power conditions, Chapter 6 – Toshiba Computer L300 User Manual

Page 103: Power and power-up modes, Power conditions -1

background image

User’s Manual

6-1

L300/L300D series

Chapter 6

Power and Power-up Modes

The computer’s power resources include the AC adaptor and internal

batteries. This chapter gives details on making the most effective use of

these resources including charging and changing batteries, tips for saving

battery power, and power-up modes.

Power conditions

The computer’s operating capability and battery charge status are affected

by the power conditions: whether an AC adaptor is connected, whether a

battery is installed and what the charge level is for the battery.

Power conditions

Power on

Power off

(no operation)

AC adaptor

connected

Battery fully

charged

• Operates
• LED: Battery Green

DC IN Green

• LED: Battery Green

DC IN Green

Battery partially

charged or no

charge

• Operates
• Quick Charge
• LED: Battery Orange

DC IN Green

• Quick charge
• LED: Battery Orange

DC IN Green

No battery

installed

• Operates
• No charge
• LED: Battery off

DC IN Green

• No charge
• LED: Battery off

DC IN Green