4 Configuring the Receiver
3 4 AgGPS 252 Receiver User Guide
Note – The AgRemote utility, when connected to an AgGPS 252 receiver
receiver, automatically resets the receiver port communication settings to
8-O-1 TSIP 115 K. This enables optimal communication with an office
computer. If the receiver is to work with an Autopilot system, however, the
receiver port communication settings must be 8-N-1 TSIP 38.4 K. To work
with some other devices and software programs, the receiver port
communication settings must be 8-N-1 NMEA 4800. If AgRemote has
changed the settings, you will need to change them back manually.
When using a Trimble SiteNet 900 radio, make sure that the
communication settings are correct in the receiver.
The default settings to use with the SiteNet radio are:
Changing the input or output port settings
1.
From the Port A Config screen, press
2
until the Port-A
Input/Output screen appears:
2.
Press
3
to activate the cursor.
3.
Press
1
or
2
to change the value.
4.
Press
3
.
5.
Repeat Steps 3 and 4 until you have set all the required values.
6.
Press
4
to save all the changes.
7.
Press
2
to move to the next screen.
Setting
Description
Baud rate
38,400
Data bits
8
Parity
None
Stop bits
1
åæ I RTCM 9600
8N1 0 NMEA 4800