Per Line Setup Window—Phone Mode Configuration
Click Dial Timeout Field
The Click Dial Timeout field identifies the amount of time, in seconds, the phone rings before hanging up.
The range for this field is 10 to 60 sec.
The Monitor Relay field provides the IP-223 the ability to decode a valid Ethernet packet and provide a relay-contact output
to turn off the sub-audible-tone-decoder circuit in the radio receiver. This allows the console operator to monitor the line for
other users before transmission (required by FCC regulations on stations equipped with CTCSS). Select one of the following
operating modes for the monitor relay:
Reset with PTT – When selected, the monitor relay is closed from the time the monitor tone sequence is received until the
next PTT operation.
On except PTT –When selected, the monitor relay is latched at all times except when PTT is active, whether the monitor
function tone is received or not.
Timed – When selected, enter the amount of time, in ms, the monitor relay is latched.
Relay Closure
R1 - Ring Check Box
The R1 - Ring check box indicates whether or not the R1 relay opens and closes in step with the ring cadence. If selected,
the R1 relay opens and closes in step with the ring cadence.
FIGURE 106.
Per Line Setup - Phone Mode (view 2)
Monitor Relay
Options