Toshiba P503DL User Manual
Page 12
12
UNSWITCHED 8A MAX
ON
OFF
POWER
AC100~ 240 50/60Hz
AC INLET
AC100~ 240 50/60Hz
AC OUT INLET
( 2 )
( 3 )
( 1 )
FUNCTION OF POWER PANEL
Note 1: The AC outlet supplies un-switched power source to a
second unit in a multi-projection system.
Do not use it for any other purpose. Serial connection
using this power outlet must be maximum of four units
including the 1st unit.
Note 2: The plug type of the projection unit power cable may not
match the AC outlet. When power is to be supplied
to another unit from this AC outlet, please purchase
necessary power cable.
Note 3: About Power Supply cord
The Power Supply cord must be in accordance with
the applicable standards.
A three -core cord, one for ground, must be used.
The power cord must be at least 1.0mm
2
and H05VV-F.
No. Name
Function
Remarks
1 Power Switch
Turn ON and OFF main power
ON/OFF
2 AC Inlet
AC 100-240V, 50/60Hz input
3P plug
3 AC Outlet
AC outlet, un-switched, max 8A
3P socket
POWER SWITCH AND POWER INDICATOR
AC power source is turned-on/off with the Power Switch. When the Power Switch is turned -on, the Power
Lamp LED Indicator lights in green, Fan indicator by green and some periods later, green at Lamp when
lamp is ON and the projection unit enters active state.
It takes about 30 seconds typically till an image is shown after Power Switch is turned-on.
In the active state, it is possible to power on/off with an external controller. When power is turned-off with
an external controller, the Power Indicator LED lights in red color and a projection unit enters standby
state.
Interval from turn-off to turn -on shall be more than 30 seconds. If the interval is not enough, the lamp
may not strike, longer the wait time, lamp life risk becomes less. If the user continues to repeat this
short wait re-strike, it may shorten the life of the lamp.
The power/lamp/fan indicators also indicate failure information of the projection unit by blinking light.
The later page at appendix list shows the lamp status.