Appendix – Specifications

Station Loop Lengths

Strata CTX General Description 11/02

77

Station Loop Lengths

In a single site installation, the Base and optional Expansion Cabinets must be placed within the
allowed maximum distance of each other as designated by

Table 26

.

Table 26

Station Loop Lengths

1

1. When the system is powered by backup battery, range may be less as the backup battery is

discharged.

Mode

Maximum line length (24 AWG)

1 Pair

2 Pair

1 Pair plus

external power

2

2. Two-pair wiring or optional telephone power supply is required to achieve maximum range in all cases.

DKT3000 or DKT2000-
series

3

3. BDKS does not provide the power wire pair, an external power supply is required to achieve maximum

range.

1000 ft. (303m)

1000 ft. (303m)

1000 ft. (303m)

DKT with BVSU or
DVSU

DKT with

BHEU or HHEU

DKT with BPCI

DKT with BPCI + BHEU

DKT with BVSU + BHEU
or DVSU + HHEU

DKT with DADM3020 or
DADM2020 (1 ADM)

675 ft. (204m)

DKT with DADM3020 or
DADM2020 (2 ADMs)

500 ft. (151m)

DDSS3060 or
DDSS2060

1000 ft. (303m)

BATI, RATI

n/a

n/a

DDCB3

1000 ft. (303m)

1000 ft. (303m)

Standard telephones,
voice mail, AA, etc.

Approx. 3000 ft.
(909 m) with 150
ohm device.

4

4. See manufacturer’s product specifications for exact resistance of device.

n/a

n/a

Approx. 9000 ft.
(2727 m) with 150
ohm device.

4

Approx. 21000 ft.
(6363 m) with 150
ohm device.

4