Self test error messages, A self test error messages, Appendix a self test error messages – Texas Instruments EXTENSA 570CD User Manual
Page 74: Introduction
Appendix A
Self Test Error Messages
A.1
Introduction
This appendix contains reference data useful in diagnosing and correcting self test
errors.
Table A-1 Self Test Error Messages
Error Message
Corrective Action
CMOS Battery Bad
Replace main board
CMOS Checksum Error
Cycle power to Notebook; if
problem persists, replace main
board.
Disk Boot Failure
Insert a system disk in drive A
Diskette Drive Controller Error or No
Controller Present
Cycle power to Notebook; if
problem persists, replace main
board.
Diskette Drive Error
Insert Diskette and retry; if
problem persists, replace drive.
Diskette Drive Type Mismatch
Press Ctrl-Alt-Esc to reconfigure
the system.
Equipment Configuration Error
Press Ctrl-Alt-Esc to reconfigure
the system.
Hard Disk 0 Error
Cycle power to Notebook; if
problem persists, replace main
board and/or hard drive.
Hard Disk 0 Extended Type Error.
Cycle power to Notebook; if
problem persists, replace hard
drive.
Insert system diskette and press key to
reboot
Insert a system disk in drive A
I/O Parity Error
Cycle power to Notebook; if
problem persists, replace main
board.
Keyboard Error or No Keyboard
Connected
Cycle power to Notebook; if
problem persists, check keyboard
cable conections to main board; if
problem persists, replace keyboard
and or main board.
Error Messages A-1