Appendix A: Specifications

A–2

Option 01 VXI Interface Module User Manual

Table A–1: VXI Instrument Characteristics

Characteristics

Description

EN 55011, Class A

The instrument complies with the requirements of EN 55011 for radiated, conducted,
and magnetic emissions, when installed in a suitable VXI chassis. A suitable VXI
chassis is defined as one which contains adequate EMC shielding which makes
contact with the RF gasket on the front and rear shields of the VX43xx Module.

FCC

The instrument complies with the requirements of FCC CFR 47, Part 15, Subpart B,
Class A for radiated and conducted emissions.

Table A–2: Environmental/Reliability Characteristics

Characteristics

Description

Temperature

Operating

Meets or exceeds MIL-T-28800E for Type III, 0 to 50

_ C external ambient, when

operated in a mainframe providing Class 3 equipment.

Non-operating

–40

_ C to +71_ C

Airflow as required by the host module, –10

_ C/55_ C for 10_ C (or less) temperature

rise of internal air, as measured at the cooling air exit points, and with no heat transfer
either to or from any adjacent VXI modules.

Relative Humidity

Operating

Up to 95% at up to 30

_ C, and up to 45%, at up to 50_ C.

Non-operating

Up to 95%, at up to 50

_ C.

Altitude (1) Operating

6,000 ft. altitude.

Altitude (2)

Meets or exceeds MIL-T-28800E for Type III, (operating to 10,000 ft., non-operating to
15,000 ft.). Derate maximum operating temperature above TBD ft. by degree C per
1000 ft.

Table A–3: Option 01-Specific Characteristics

Characteristics

Description

VME Interrupter Level

Switch selectable to a level between 1 and 7.

VXI Logical Address

Switch selectable to a value between 0 and 255.

VXI Dynamic Addressing

Not supported.

Contents of device/manufacturer dependent
VXI registers.

ID Register

BFFD hexadecimal.

Device Type

Set according to the model number of the slave module that the interface is installed
on as specified in the following table. (Convert the last 3 digits of the model number to
hex, take the one’s complement, AND with F7FF.)