Tektronix 070-9180-01 User Manual
Page 96

Status and Events
Option 01 VXI Interface Module User Manual
4–7
Table 4–5: Command Error Messages (Bit 5 in Standard Event Status
register) (Cont.)
Code
Message
–121
Invalid character in number
–123
Exponent too large
Table 4–6 lists the execution error messages that can occur during execution of a
command. Parameter y in these error messages represents the local bus address
of the module that the error message applies to. A value of 1 indicates the
module containing the Option 01 daughter board, a value of 2 the module in the
next slot to the right, and so on.
Table 4–6: Execution Error Messages (Bit 4 in Standard Event Status
register)
Code
Message
–200
Execution error; Reserved
–200
Execution error; scan list undefined
–211
Trigger ignored
–213
Init ignored
–222
Data out of range; Channel number x on module y
–222
Data out of range; Channel number x!x on module y
–222
Data out of range; Channel number x!x!x on module y
–222
Data out of range; Invalid module address specified
–222
Data out of range; Invalid section number
–222
Data out of range; invalid sequence count
–222
Data out of range; invalid trigger delay
–222
Data out of range; Invalid VXI TTL Trigger level
–222
Data out of range; Maximum value for ESE command is 255
–222
Data out of range; Maximum value for SRE command is 255
–222
Data out of range; invalid dwell time specified.
–223
Too much data; channel list array overflow
–223
Too much data; Input buffer overflow
–223
Too much data; Output buffer full
–223
Too much data; scan list array overflow
–240
Hardware error; shift register verification error – module m
–241
Hardware error; Unrecognized module d, d
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com