beautypg.com

Telenetics 2185 User Manual

Page 46

background image

Telenetics 2185

3-24

Table 3-13. Switch Two Settings – 2185 A

Switch

Segment

Setting

Reason

2-1

Up

Control Signal Contention

2-2

Down

Asynchronous operation

2-3

XX

Does not matter; on for sync only

2-4

XX

Depends on line conditions

2-5

XX

Does not matter, since unit is set
for async. operation

2-6

XX

2-7

Down

RTS/DCD on all the time

2-8

XX

Does not matter (Main Ch DTE)

Table 3-14. Switch Three Settings – 2185 A

Switch

Segment

Setting

Reason

3-1

Up

Main Channel connection to DTE

3-2

Up

Subchannel one connection to DTE

3-3

Down

Subchannel two connection to DCE

3-4

XX

Subchannel three not used

3-5

XX

Subchannel four not used

3-6

XX

Subchannel five not used

Table 3-15. Switch One Settings – 2185 B

Switch

Segment

Setting

Reason

1-1

Down

Enable Subchannel 1

1-2

Down

Enable Subchannel 2

1-3

Down

Enable Subchannel 3

1-4

Down

Enable Subchannel 4

1-5

Down

Enable Subchannel 5

1-6

Up

The settings of these three
switches set the data rate
(1. 2 kpbs)

1-7

Up

1-8

Down